Engineering Excellence in Motion: Our Product Portfolio

Discover our comprehensive range of innovative, high-efficiency electric motors and drive systems, engineered to deliver reliability across the most demanding industrial applications globally.

IEC motors

IEC motors
Type of protection:
Safe Area
Power range:
0.06kW to 2000kW
Frame size:
56 – 710
Number of poles:
2, 4, 6, 8 and more
Ingress protection:
IP 23, IP 55 and higher
Thermical class:
155 (F), 180 (H)
Method of cooling:
TEFC, ODP
ATB Logo

IEC Low Voltage Motors

ATB High Efficiency Motors IE2

ATB High Efficiency Motors IE2

Motor type:WE2
Power range:0.18kW to 375kW
Frame size:80 – 355
Number of poles:2, 4, 6, 8
Temp class:155 (F), 180 (H)
Cooling:TEFC, ODP, CACA, CACW
Download Catalog IE2
ATB Premium Efficiency Motors IE3

ATB Premium Efficiency Motors IE3

Motor type:WE3
Power range:0.18kW to 375kW
Frame size:80 – 355
Number of poles:2, 4, 6, 8
Temp class:155 (F), 180 (H)
Cooling:TEFC, ODP, CACA, CACW
Download Catalog IE3
ATB Super Premium Efficiency Motors IE4

ATB Super Premium Efficiency Motors IE4

Motor type:WE4
Power range:0.18kW to 375kW
Frame size:80 – 355
Number of poles:2, 4, 6, 8
Temp class:155 (F), 180 (H)
Cooling:TEFC, ODP, CACA, CACW
Download Catalog IE4
ATB Ultra Premium Efficiency Motors IE5

ATB Ultra Premium Efficiency Motors IE5

Motor type:WE5
Power range:0.18kW to 375kW
Frame size:80 – 355
Number of poles:2, 4, 6, 8
Temp class:155 (F), 180 (H)
Cooling:TEFC, ODP, CACA, CACW
Download Catalog IE5

IEC system motors

IEC system motors
Type of protection:
Safe Area
Power range:
500 kW to 4800kW
Frame size:
400 – 710
Number of poles:
2, 4, 6, 8 and more
Ingress protection:
IP 23, IP 55 and higher
Thermical class:
155 (F), 180 (H)
Method of cooling:
TEFC, CACA, CACW

NEMA motors

NEMA motors
Type of protection:
Safe Area
Frame size:
56 – 586
Number of poles:
2, 4, 6, 8
Ingress protection:
IP 55
Temperature class:
155 (F), 180 (H)
Method of cooling:
TEFC

3-phase induction (asynchronous) motors 2-pole / 4-pole

3-phase induction motors
Type of protection:
Safe Area / Ex e, Ex n, EX p, Ex d, Ex de
Power range:
up to 25 MW
Frame size:
up to 1700
Number of poles:
all
Ingress protection:
IP 23, IP 55 and higher
Temperature class:
155 (F), 180 (H)
Method of cooling:
Open Vent, TEFC, CACA, CACW, TEWJ

High Speed Machines

High Speed Machines
Type of protection:
Safe Area
Power range:
50 – 1.000 kW
Frame size:
180 – 400
Number of poles:
bis 15.000 U/min
Ingress protection:
IP 23 + IP 55
Temperature class:
150 (F), 180 (H)
Method of cooling:
ODP, CACW

Single phase motors

Single phase motors
Type of protection:
Safe Area
Power range:
0,07 – 2,2 kW
Frame size:
56 – 100
Number of poles:
4
Ingress protection:
IP 55
Temperature class:
F / H
Method of cooling:
TEFC

Slip ring motors

Slip ring motors
Type of protection:
Safe Area
Power range:
up to 1100kW
Frame size:
160-560
Number of poles:
2, 4, 6, 8 and more
Ingress protection:
IP 23, IP 55
Temperature class:
F
Method of cooling:
TEFC / CACA / CACW / ODP

Motors for hazardous atmospheres

Motors for hazardous atmospheres
Type of protection:
Ex e, Ex n, Ex d, Ex de
Power range:
0.06kW to 2000kW
Frame size:
63-560
Number of poles:
2, 4, 6, 8 and more
Ingress protection:
IP 55 and higher
Temperature class:
155 (F), 180 (H)
Method of cooling:
TEFC

Home appliance motors

Home appliance motors
Type of protection:
Safe
Power range:
0.01kW to 5.5kW
Frame size:
45 – 112
Number of poles:
4
Ingress protection:
IP 55
Temperature class:
F
Method of cooling:
N/A

3-phase induction (asynchronous) motors 2-pole / 4-pole

3-phase induction motors
Type of protection:
Safe Area, Ex d, Ex n, Ex p
Power range:
20kW to 25MW
Frame size:
225-1000 and above
Number of poles:
2, 4
Ingress protection:
up to 56
Temperature class:
F / H
Method of cooling:
TEFC, CACA, CACW, Open vent, TEWJ

Synchronous motors

Synchronous motors
Type of protection:
on request
Power range:
up to 25MW
Frame size:
up to 1400
Number of poles:
to suit
Ingress protection:
IP 23, IP 55
Temperature class:
155 (F), 180 (H)
Method of cooling:
CACA, CACW and special cooling

Slip ring motors

Slip ring motors
Type of protection:
Safe Area
Power range:
up to 13.2MW
Frame size:
355 to 1120
Number of poles:
2, 4, 6 and more
Ingress protection:
IP 23, IP 55
Temperature class:
155 (F)
Method of cooling:
CACA, CACW, ODP

Motors for hazardous atmospheres

Motors for hazardous atmospheres
Type of protection:
Ex e, Ex n, Ex p, Ex d, Ex de
Power range:
up to 25MW
Frame size:
up to 1700
Number of poles:
all
Ingress protection:
IP 55 and higher
Temperature class:
155 (F), 180 (H)
Method of cooling:
TEFC, TEWJC, CACW

Asynchronous generators

Asynchronous generators
Type of protection:
Safe Area
Power range:
up to 10MW
Frame size:
up to 1000
Number of poles:
2, 4, 6, 8 and more
Ingress protection:
IP 23, IP 55
Temperature class:
155 (F)
Method of cooling:
TEFC / TEWJC / CACW / CACA / ODP

Synchronous generators

Synchronous generators
Type of protection:
Safe Area
Power range:
up to 10MW
Frame size:
up to 1700
Number of poles:
4
Ingress protection:
up to 56
Temperature class:
F
Method of cooling:
CACA / CACW / TEFC

Hydro generator

Hydro generator
Type of protection:
Safe Area
Power range:
up to 30 MVA
Number of poles:
4-24
Ingress protection:
IP 56
Temperature class:
F
Method of cooling:
on demand

Wind / wave energy solutions

Wind / wave energy solutions
Type of protection:
Safe Area
Power range:
up to 2000 KW
Frame size:
up to 900
Number of poles:
4-20
Ingress protection:
55 or higher for sub-sea
Temperature class:
155 (F), 180 (H)
Method of cooling:
CACA / CACW/ TEWJC

Smoke extraction motors

Smoke extraction motors
Type of protection:
Safe Area – 200C, 400C, 600C
Power range:
up to 1000 kW
Frame size:
80-500
Number of poles:
4
Ingress protection:
up to 56
Temperature class:
155 (F), 180 (H)
Method of cooling:
TEFC

Semihermetic motors

Semihermetic motors
Type of protection:
Safe Area
Power range:
Special design – upon request
Frame size:
Special design – upon request
Ingress protection:
IP 67
Temperature class:
F / H
Method of cooling:
N/A

Motors with higher sealing

Motors with higher sealing
Type of protection:
Safe Area
Power range:
Special design – upon request
Frame size:
Special design – upon request
Ingress protection:
IP 67
Temperature class:
155 (F), 180 (H)
Method of cooling:
N/A

Axial airgap motors

Axial airgap motors
Type of protection:
N/A
Power range:
0.11 to 2.2kW
Frame size:
N/A
Number of poles:
4
Ingress protection:
N/A
Temperature class:
F
Method of cooling:
N/A

Industrial DC motors (Bull Electric)

Industrial DC motors
Type of protection:
Safe Area
Power range:
0.09 to 15kW
Frame size:
up to 355
Number of poles:
4
Ingress protection:
IP55
Temperature class:
F
Method of cooling:
TEFC

Overhung compressor motors

Overhung compressor motors
Type of protection:
Safe Area
Power range:
up to 1MW
Frame size:
N/A – equivalent 560
Number of poles:
12, 16
Ingress protection:
up to IP55
Temperature class:
F / H
Method of cooling:
TEFC / Open ventilated

High slip motors (5-15% NEMA)

High slip motors
Type of protection:
Safe Area
Power range:
200 – 9.000 kW
Frame size:
355 – 1120
Number of poles:
2 – 12
Ingress protection:
IP55
Temperature class:
B
Method of cooling:
IC01, IC511, IC611, IC81W
Options:
IM B3, IM V1

Low voltage motor internals (stators / rotors)

Low voltage motor internals
Power range:
on request
Frame size:
on request
Number of poles:
on request
Ingress protection:
on request
Temperature class:
155 (F)
Method of cooling:
on request

High voltage motor internals (stators / rotors)

High voltage motor internals
Power range:
as per request
Frame size:
N/A
Number of poles:
any
Ingress protection:
N/A
Temperature class:
F / H
Method of cooling:
N/A

Mining motors – conveyor / shearer

Mining motors
Type of protection:
Ex d 1M
Power range:
200kW to 2MW
Frame size:
up to 630
Number of poles:
4
Ingress protection:
IP56
Temperature class:
H
Method of cooling:
TEWJC

More Special Products

More Special Products
  • Motors for circular saws and wood working
  • Water-cooled special motors
  • Exciters for permanent magnets
  • Exciters for synchronous machines
  • Nuclear power motors
  • Military defence motors
  • Built-in motors
  • Motors for ethylene reactors
  • Drilling motors

System Solutions

System Solutions
Type of protection:
Safe area
Power range:
up to 4MW
Frame size:
N/A
Number of poles:
all
Ingress protection:
up to IP56
Temperature class:
F
Method of cooling:
TEFC / TEWJC

Suction blowers and fan systems

Suction blowers and fan systems

Suction blowers with radial and axial fan
Complete motor system including mounting, impeller and housing.

Customized solution
for aggressive environments and high ambient temperatures.

Contact

ATB Austria Antriebstechnik AG
Opernring 1 E 220
1010 Vienna
Austria

Phone: +43 1 902 50 0
Fax: +43 1 902 50 110
E-mail: info@atb-motors.com